SMART-ITL

> Research & Development > R&D Facilities > SMART-ITL

SMART Integral Effect Test Facility (SMART-ITL)

SMART, an Integral Type Reactor

  • Design Concepts
  • 365 MWth integral type of pressurized light-water reactor
  • Electricity production (90,000 kW/day) + desalination (40,000 tons/day)
  • Integral arrangement of reactor assembly in a single vessel
  • Passive safety systems : PRHRS, PSIS, ADS & PCCS
  • Elimination of LBLOCA* possibility
  • Major concern for safety analysis : SBLOCA** scenario
SMART-ITL_img6

Pressurized Water Reactor | SMART Reactor

Purpose of Tests

  • Validation of Component Performances & Safety for Design Basis Accident (DBA)
  • Integral Validation for SMART SDA & Predictability of Safety Analysis Codes
  • Technical Support for Domestic and Overseas Constructions of SMART
SMART-ITL_img4

The Exterior of SMART-ITL

Technical Specification of SMART-ITL

  • Reference Reactor: SMART
  • Core power : 365 MWth
  • Design press. & temp. : 17.0 MPa / 350 ℃
  • Mass flow rate in core : 2,507 kg/s
  • SMART-ITL Building
  • Building size : 30 X 27 X 45 m (underground : 16.8 X 16.8 X 10 m)
  • Structure height : 45 m (Cranes : 25 ton, 10 ton)
  • Design Characteristics
  • Major scaling ratio → Length, height, time : 1/1; Area, volume : 1/49
  • SG & PRHRS & PSIS : 4 trains
  • Design press. & temp.: 170 bar, 350 ℃
  • Maximum core heater power : 2.0 MW (30% of scaled full power)
  • Major systems : Primary/Secondary Systems, Safety Injection System (SIS), Passive Safety Injection System (PSIS), Passive Residual Heat Removal System (PRHRS), Break System (BS), Break Measuring System (BMS), Auxiliary System
SMART-ITL_img2

SMART ITL